Home > Multiparameter > Multiparameter Portable Meters
HI 9829
HI 9829
Multiparameter Meter
pH/ ORP/ ISE, EC/ TDS/ Resistivity/ Salinity/ Seawater Specific
Gravity, Turbidity, DO, Temperature and Atmospheric Pressure
Get a Quote
Field replaceable ISO 7027 compliant turbidity sensor
Ammonium, chloride and nitrate ISE’ s
Logging from probe or meter
Fully customizable instrument, probe, sensors and measurement
specifications
Display from 1 to 12 parameters with font dimension adjustment
Field replaceable sensors
pH/ ORP or pH, four electrode EC and galvanic DO sensors
Auto-recognition of all sensors
Rugged probe with stainless steel tip has a diameter under 2” for wells
and pipes
Fast Tracker™ — Tag I.D. System simplifies periodic monitoring
Features a built-in barometer for DO compensation
Quick or independent sensor calibration feature
Measurement check eliminates erroneous readings
Logged data can be displayed as graphs
Graphic LCD with backlight
USB for PC connectivity
Good Laboratory Practice feature with last five calibrations recorded
Meter accepts both alkaline and rechargeable batteries
Waterproof protection for meter ( IP67) and probes ( IP 68)
Rugged, waterproof and easy to use, the HI 9829 is the ideal meters for
field measurements of lakes, rivers and seas. Both meters display 1 to
12 parameters simultaneously from up to 15 user selectable parameters.
Combined with one of the HI 76x9829 series probes, the HI 9829 can
measure water quality parameters such as pH, ORP, conductivity,
turbidity, temperature, ions ions ammonium, nitrate, chloride ( NH4+ ,
NO3-— N or Cl-) , dissolved oxygen concentration, resistivity, TDS,
salinity, and seawater specific gravity. Atmospheric pressure is
measured for DO compensation.
This meter features a graphic, backlit LCD that scales digits to fit up
to 12 parameters and allows full configuration of each parameter
measured along with an on-screen graphing capability.
HI 9829 incorporates comprehensive GLP features and the transferring of
data via USB connection. The HI 98290’ s HELP key displays context
sensitive help. The alpha-numeric keypad offers a user friendly way to
complete the input fields.
The Perfect Monitoring Tool
Water scientists and managers alike utilize data-collection programs as
part of environmental monitoring. These programs are designed to reveal
changes in water and the environment around it over time. Reliable,
dependable measurements are required to monitor these changes and
understand the contributions from seasonal fluctuations, weathering, as
well as manmade pollution. The HI 7629829 or HI 7639829 intelligent
autonomously logging probes can be left at the application site to
autonomously log results without the aid of the HI 9829 or a PC. When it
is time to retrieve the results the measurement data can be easily
transferred to the meters or PC using HI 929829 software.
Sensors
Sensor replacement is quick and easy with screw type connectors and
color coded sensors. The HI 9829 automatically recognizes sensor
presence.
The HI 7609829-2 galvanic DO sensor with its fast response time can be
ready at a moment’ s notice. This probe features a replaceable membrane
cap for easy maintenance.
The HI 7609829-3 4-electrode conductivity probe uses a polarographic
measurement principle and ensures stable conductivity readings that are
immune to polarization or surface coating. Absolute conductivity,
temperature compensated conductivity, salinity, specific gravity and TDS
determinations are possible with measurements from this sensor.
The new HI 7609829-4 EC/ turbidity sensor is field replaceable and
offers readings from both parameters at the same time.
All potentiometric sensors feature a double junction design and are gel
filled to increase resistance to contamination. An ISE sensor can be
used in place of the pH sensor and is automatically recognized. pH in mV
readings are also displayed — ideal for troubleshooting.
A Great Combination
The use of HANNA’ s microprocessor based multiparameter intelligent
probes with HI 9829 meter will provide reliable data collection that can
lead to an improved scientific understanding of the interconnections
between natural, chemical and geological processes and man made
pollution to effectively evaluate applications for waste-discharge
permits, remediate contaminated sites and to protect or restore
biological resources.
The HI 76x9829 probes utilize field replaceable sensors with
auto-recognition. The sensors are housed with the probe electronics in a
rugged housing with a water-tight cable connection. The base probe
model permits the measurement of conductivity, pH/ ORP ( or an ISE) ,
and dissolved oxygen. Other models permit turbidity and logging.
The probes are available with a choice of cable lengths such as 4 m and
10 m and 20 m ( 13, 33’ ) that utilize a DIN connection to interface
with the meters. The probes are supplied with a maintenance kit in the
carrying case versions. These new probes can be connected directly to a
PC with the HI 96982910 USB adapter, and the HI 929829 PC software to
communicate directly with the probes.
Reliable temperature measurements are a critical parameter of aquatic
system monitoring. Temperature and temperature changes due to water
releases can affect the ability of water to hold oxygen as well as the
ability of organisms to resist certain pollutants. The intelligent
probes incorporate an accurate thermistor that changes predictably with
temperature changes. Accurate temperature reading in degrees Celsius,
Kelvin or Fahrenheit are displayed and utilized by other detectors for
temperature correction.
The pH or pH/ ORP sensors incorporate the technology that has made
HANNA so successful as a pH manufacturer. Reliable pH measurements are
one of the most important indicators of water chemistry indicating the
relative amount of free hydrogen and hydroxyl ions in the water. HANNA’ s
pH sensors utilize a resilient PEI body to protect them from solid
particulates found water samples. Consistency and quality are the
hallmarks of these sensors. Our differential measurement system further
enhances the measurement reliability providing temperature corrected pH.
A choice of 3 ion selective electrodes is available for constant
reporting of common surface water contaminants. Nitrate, ammonium and
chloride are available. Each ISE is a combination electrode
incorporating an extremely constant reference spiral; all
potentionmetric probes feature a double junction and solid gelled
reference design. By utilizing conductivity, the HI 9829 can convert ion
activity measurements to concentration units.
The HANNA 4-electrode conductivity probe using the polarographic
measurement principal ensures stable conductivity readings. Electrolytic
conductivity measures of the ability of water to conduct an electrical
current. It is highly dependent on the amount of dissolved solids ( such
as salt) in the water. Absolute conductivity, temperature corrected
conductivity, salinity, specific gravity and water hardness ( TDS)
determinations are possible with measurements from this sensor.
The oxygen dissolved in lakes, rivers, and oceans is crucial for the
organisms and creatures living in it. If dissolved oxygen concentrations
drop below normal levels in water bodies, the water quality degrades
and the organisms begin to die off. The galvanic sensor does not require
long polarization times so is ready for measurement at a moment’ s
notice. Our sensor also utilizes a replaceable cap design for ease of
maintenance and a safe non-toxic electrolyte. DO readings are
compensated for the effects of temperature ( using the probes built-in
temperature sensor) and atmospheric pressure ( using the HI 9829’ s
internal atmospheric pressure sensor) .
The new HANNA turbidity sensor is a replaceable design for
instantaneous turbidity reading that conforms to ISO 7027 standards. It
provides measurements from 0.0 to 50.0 FNU; and 50 to 1000 FNU.
Turbidity is the amount of particulate matter that is suspended in
water. Turbidity measures the scattering effect that suspended solids
have on light: the higher the intensity of scattered light, the higher
the turbidity. Material that causes water to be turbid include: clay,
silt, finely divided organic and inorganic matter, soluble colored
organic compounds, plankton and microscopic organisms.
Probes with the logging function have a logging memory that allows
storage of up to 140, 000 individual samples or 12, 000 complete sample
data sets with date and time stamp thus permitting up to a 35 day
deployment with all channels logging at 10 minute intervals. Logging
probes work with either rechargeable or standard batteries
The probe incorporates a temperature sensor for temperature
compensation of all parameters.
Monitoring and Tracking
When data collection or monitoring requires tracking capabilities, two
kinds of methods can be included with the data— timestamp and location.
The timestamp expresses the date and the time when the measurement was
taken. The time and date ( timestamp) are determined by the internal
real time clock of the HI 9829. As for location of measurement, the HI
9829 offers the FastTracker™ Tag ID system using ID encoded TAGs mounted
at the location sites. Users simply touch the TAG receiver to the
mounted TAG to store data along with location ID.
Fast Tracker™ — Tag Identification System
HANNA’ s Fact Tracker™ — Tag Identification System simplifies test
logging. iButton® s with a unique ID can be installed at various
sampling sites. When the matching connector on the meter contacts the
location button, measurements are logged and labeled with the
alphanumeric user-entered location ID. Location, date, time and
measurements are logged into the meter which can be transferred to a PC.
The Fast Tracker™ system complements the GPS for ultimate tracking.
iButton® Tags are Easy to Install
Install the optional TAGs near your sampling points for quick and easy
iButton® readings. Each TAG contains a computer chip with a unique
identification code encased in stainless steel. You can install a
practically unlimited amount of TAGs. Additional TAGs can be ordered for
all of your traceability requirements.
* Google™ is a registered trademark of Google™ , inc. HANNA
Instruments® has no affiliation with Google™ .
METER ONLY, CARTON BOX PACKAGING
HI 9829-01 Meter only, charging adapter and instruction manual, 115VAC
HI 9829-02 Meter only, charging adapter and instruction manual, 230VAC
METER AND PROBE ONLY, NO SENSORS, CARRYING CASE PACKAGING
HI 98291-01 HI 9829 and HI 7629829/ 4 logging probe for pH/ pH+ ORP/
ISE, DO, EC, temperature, with 4 m ( 13.1’ ) cable, probe maintenance
kit, charging adapter, instruction manual and hard carrying case, 115VAC
HI 98291-02 HI 9829 and HI 7629829/ 4 logging probe for pH/ pH+ ORP/
ISE, DO, EC, temperature, with 4 m ( 13.1’ ) cable, probe maintenance
kit, charging adapter, instruction manual and hard carrying case, 230VAC
HI 98292-01 HI 9829 and HI 7639829/ 4 logging probe for pH/ pH+ ORP/
ISE, DO, EC+ turbidity, temperature, with 4 m ( 13.1’ ) cable, probe
maintenance kit, charging adapter, instruction manual and hard carrying
case, 115VAC
HI 98292-02 HI 9829 and HI 7639829/ 4 logging probe for pH/ pH+ ORP/
ISE, DO, EC+ turbidity, temperature, with 4 m ( 13.1’ ) cable, probe
maintenance kit, charging adapter, instruction manual and hard carrying
case, 230VAC
HI 98293-01 HI 9829 and HI 7629829/ 10 logging probe for pH/ pH+ ORP/
ISE, DO, EC, temperature, with 10 m ( 33’ ) cable, probe maintenance
kit, charging adapter, instruction manual and hard carrying case, 115VAC
HI 98293-02 HI 9829 and HI 7629829/ 10 logging probe for pH/ pH+ ORP/
ISE, DO, EC, temperature, with 10 m ( 33’ ) cable, probe maintenance
kit, charging adapter, instruction manual and hard carrying case, 230VAC
HI 98294-01 HI 9829 and HI 7639829/ 10 logging probe for pH/ pH+ ORP/
ISE, DO, EC+ turbidity, temperature, with 10 m ( 33’ ) cable, probe
maintenance kit, charging adapter, instruction manual and hard carrying
case, 115VAC
HI 98294-02 HI 9829 and HI 7639829/ 10 logging probe for pH/ pH+ ORP/
ISE, DO, EC+ turbidity, temperature, with 10 m ( 33’ ) cable, probe
maintenance kit, charging adapter, instruction manual and hard carrying
case, 230VAC
Order Information:
Sensors for all meter and probe configurations are sold separately, see
configurations up above.
Range pH/ mV of pH input 0.00 to 14.00 pH/ ± 600.0 mV
ORP mV ± 2000.0 mV
Ammonium-
Nitrogen 0.02 to 200 ppm ( as N)
Chloride 0.6 to 200 ppm
Nitrate-Nitrogen 0.62 to 200 ppm ( as N)
Conductivity 0 to 200 mS/ cm ( absolute EC up to 400 mS/ cm)
TDS 0 to 400000 mg/ L or ppm ( the maximum value depends on the TDS
factor)
Resistivity 0 to 999999 © • cm; 0 to 1000.0 k© • cm; 0 to 1.0000 M© •
cm
Salinity 0.00 to 70.00 PSU
Seawater à 0 to 50.0 st, s0, s15
Turbidity 0.0 to 99.9 FNU; 100 to 1000 FNU
Dissolved Oxygen 0.0 to 500.0% ; 0.00 to 50.00 ppm
Atm. Pressure 450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2
mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa
Temperature -5.00 to 55.00° C; 23.00 to 131.00° F; 268.15 to 328.15K
Resolution pH/ mV of pH input 0.01 pH / 0.1 mV
ORP mV 0.1 mV
Ammonium-
Nitrogen 0.01 ppm to 1 ppm; 0.1 ppm to 200 ppm
Chloride 0.01 ppm to 1 ppm; 0.1 ppm to 200 ppm
Nitrate-Nitrogen 0.01 ppm to 1 ppm; 0.1 ppm to 200 ppm
Conductivity manual: 1 µ S/ cm; 0.001 mS/ cm; 0.01 mS/ cm; 0.1 mS/
cm; 1 mS/ cm; automatic: 1 µ S/ cm from 0 to 9999 µ S/ cm; 0.01 mS/ cm
from 10.00 to 99.99 mS/ cm; 0.1 mS/ cm from 100.0 to 400.0 mS/ cm;
automatic mS/ cm: 0.001 mS/ cm from 0.000 to 9.999 mS/ cm; 0.01 mS/ cm
from 10.00 to 99.99 mS/ cm; 0.1 mS/ cm from 100.0 to 400.0 mS/ cm
TDS manual: 1 mg/ L ( ppm) ; 0.001 g/ L ( ppt) ; 0.01g/ L ( ppt) ;
0.1 g/ L ( ppt) ; 1 g/ L ( ppt) ; autorange scales: 1 mg/ L ( ppm) from 0
to 9999 mg/ L ( ppm) ; 0.01 g/ L ( ppt) from 10.00 to 99.99 g/ L ( ppt)
; 0.1 g/ L ( ppt) from 100.0 to 400.0 g/ L ( ppt) ; autorange g/ L (
ppt) scales: 0.001 g/ L ( ppt) from 0.000 to 9.999 g/ L ( ppt) ; 0.01 g/
L ( ppt) from 10.00 to 99.99 g/ L ( ppt) ; 0.1 g/ L ( ppt) from 100.0
to 400.0 g/ L ( ppt)
Resistivity dependent on resistivity reading
Salinity 0.01 PSU
Seawater à 0.1 à t, à 0, à 15
Turbidity 0.1 FNU from 0.0 to 99.9 FNU; 1 FNU from 100 to 1000 FNU
Dissolved Oxygen 0.1% ; 0.01 ppm
Atm. Pressure 0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm;
0.01 kPa
Temperature 0.01° C; 0.01° F; 0.01K
Accuracy @ 20° C pH/ mV of pH input ± 0.02 pH / ± 0.5 mV
ORP mV ± 1.0 mV
Ammonium-
Nitrogen ± 5% of reading or 2 ppm, whichever is greater
Chloride ± 5% of reading or 2 ppm, whichever is greater
Nitrate-Nitrogen ± 5% of reading or 2 ppm, whichever is greater
Conductivity ± 1% of reading or ± 1 µ S/ cm, whichever is greater
TDS ± 1% of reading or ± 1 mg/ L, whichever is greater
Salinity ± 2% of reading or ± 0.01 PSU, whichever is greater
Seawater à ± 1 à t, à 0, à 15
Turbidity ± 0.3 FNU or ± 2% of reading, whichever is greater
Dissolved Oxygen 0.0 to 300.0% : ± 1.5% of reading or ± 1.0%
whichever is greater; 300.0 to 500.0% : ± 3% of reading; 0.00 to 30.00
ppm: ± 1.5% of reading or 0.10 ppm, whichever is greater; 30.00 ppm to
50.00 ppm: ± 3% of reading
Atm. Pressure ± 3 mm Hg within ± 15° C from the temperature during
calibration
Temperature ± 0.15° C; ± 0.27° F; ± 0.15K
Temperature
Compensation automatic from -5 to 55° C ( 23 to 131° F)
Logging Memory
from Meter 44, 000 records
Logging Interval 1 second to 3 hours
Computer Interface USB ( with HI 929829 software)
FastTracker™ TAG ID yes
Waterproof Protection IP67
Environment 0 to 50° C ( 32 to 122° F) ; RH 100%
Power Supply 1.5V alkaline C cells ( 4) / 1.2V NiMH rechargeable C
cells ( 4) , USB, 12V power adapter
Dimensions 221 x 115 x 55 mm ( 8.7 x 4.5 x 2.2” )
Weight 750g ( 26.5 oz.)