Thickness Gauge GM130 Ultrasonic Benetech Meter Tester Ketebalan Besi HUB 08170777190
Ultrasonic Thickness Gauge Benetech GM130
(Spesifikasi diatas Benetech GM100. Kami juga menjual Benetech GM100)
Tipe ini bisa mengukur ketebalan sampai 300 milimeter (30 cm) max
*Measuring range: 1.0~300mm (Steel)
*Accuracy: (1%H+0.1) mm
*Resolution: 0.01mm
*Sound velocity range: 1000~9999m/s
*Working frequency: 5MHz
*Minimum limit for tube measuring:
Diameter 10mm probe: Diameter 20 x 3mm (Steel)
Diameter 6mm probe: Diameter 12 x 2mm (Steel)
*Auto calibration to assure the accuracy
*Auto linear compensation: this advanced software program enhances the precision by correcting the non-linear accuracy of transducer.
*Data store/ Data recall/ Data delete function
*Sound velocity measurement
*Metric/Imperial unit selection
*Low battery indication
*Auto power off
*LCD backlight display
*Power supply: 3pcs*1.5V AAA alkaline batteries
*Dimension: 70*145*28mm
Fluke 375 True RMS AC/DC Clamp Meter Tang Ampere HUB 081398831288
Digital Clamp Meter FLUKE 375
Specifications :
Fluke 374 and 375 Range Max Resolution Accuracy
AC current via jaw 600 A 0.1 A 2 % 5 digits
AC current via iFlex (optional) 2500 A 0.1 A 3 % 5 digits
DC current 600 A 0.1 A 2 % 5 digits
AC voltage 600 V 0.1 V 1.5 % 5 digits
DC voltage 600 V 0.1 mV (375)
0.1 V (374) 1 % 5 digits
Resistance 60,4) 0.1 1 % 5 digits
Frequency (375 only) 500 Hz 0.1 Hz 0.5 % 5 digits
Capacitance 1 F to 1000 F 1 F 1 % 4 digits
True-rms
Continuity
Hold
Backlight
Min/Max
Inrush
Low pass filter Fluke 375 only
18 in iFlex Flexible Current Probe Optional accessory
10 in iFlex Flexible Current Probe Optional accessory
Wire capacity 750 MCM or 2-500 MCM
Safety rating CAT III 1000 V, CAT IV 600 V
Ordering information
374 True-rms AC/DC
Clamp Meter
375 True-rms AC/DC
Clamp Meter
Optional accessories
i2500-10 iFlex Flexible
Current Probe, 10 inches
i2500-18 iFlex Flexible
Current Probe, 18 inches
Models Feature Changes
Old model: Fluke 337
New model: Fluke 376 Includes all 337 features plus:
CAT IV 600 V, CAT III 1000 V
iFlex 2500 A ac
1000 V ac/dc
mV dc
60 k
1000 F
Old model: Fluke 336
New model: Fluke 375 Includes all 336 features plus:
CAT IV 600 V, CAT III 1000 V
Optional iFlex 2500 A ac
mV dc
60 k
1000 F
Min/Max/Avg
New model: Fluke 374 Includes all 336 features
(except low pass filter) plus:
CAT IV 600 V, CAT III 1000 V
Optional iFlex 2500 A ac
1000 F
Min/Max/Avg
Old model: Fluke 335
New model: Fluke 374 Includes all 335 features plus:
CAT IV 600 V, CAT III 1000 V
Optional iFlex 2500 A ac
600 A ac/dc
1000 F
Min/Max/Avg
New model: Fluke 373 Includes all 335 features
(except inrush) plus:
CAT IV 300 V, CAT III 600 V
1000 F
Old model: Fluke 334
New model: Fluke 374 Includes all 334 features plus:
CAT IV 600 V, CAT III 1000 V
Optional iFlex 2500 A ac
True-rms
600 A ac/dc
1000 F
Min/Max/Avg
New model: Fluke 373 Includes all 334 features
(except inrush) plus:
CAT IV 300 V, CAT III 600 V
True-rms
1000 F
JUAL LUTRON PH,ORP,CD,TDS,DO Meter Lutron WA-2015 WA 08170777190
TOKOMARGASETIA
WA 08170777190
Features:
* Bench meter for multi purpose operation : PH/ORP, DO, CD/TDS Measurement.
* pH : 0 to 14.00 pH, ORP : 1999 mV.
* Conductivity : 200 uS/2 mS/20 mS/200 mS.
* Dissolved oxygen : 0 to 20.0 mg/L.
* ATC ( automatic temperature compensation ).
* Real time 16,000 no. data logger.
* Data hold, Record ( Max., Min. ), RS232
* Optional electrode : pH, ORP, CD, DO ATC electrode, ATC probe.
* DC 1.5V ( UM-3, AA ) x 4 or DC 9V adapter in.
Kelengkapan Sensor Probe
A.
pH / ORP (mV)
pH Range 0 to 14 pH
Resolution 0.01 pH
Accuracy (0.02 pH + 2 d)
Optional product for pH:
pH Electrode Optional : PE-03, PE-08, PE-21
pH 7 buffer solution pH-07
pH 4 buffer solution pH-04
ORP
-1999 mV to 1999 mV
Resolution 1 mV
Accuracy (0.5% + 2 d)
Optional product for ORP:
ORP-14 ORP Probe
ATC ( automatic temperature probe ) TP-07 0 to 65 .
B
Conductivity
Range Measurement Resolution Accuracy
200 uS 0 to 200.0 uS 0.1 uS (2% F.S.+1d) *
2 mS 0.2 to 2.000 mS 0.001 mS
20 mS 2 to 20.00 mS 0.01 mS
200 mS 20 to 200.0 mS 0.1 mS
TDS
Range Measurement Resolution Accuracy
200 PPM 0 to 132 PPM 0.1 PPM (2% F.S.+1d)
2,000 PPM 132 to 1,320 PPM 1 PPM
20,000 PPM 1,320 to 13,200 PPM 10 PPM
200,000 PPM 13,200 to 132,000 PPM 100 PPM
Optional product :
CDPB-03 Conductivity & TDS Probe
1.413 mS Conductivity Standard Solution CD-14
C. Dissolved oxygen
Measurement DO 0 to 20.0 mg/L ( liter ).
& Range Oxygen in Air 0 to 100 %.
Temperature 0 to 50 .
Resolution Dissolved Oxygen 0.1 mg/L.
Oxygen in Air 0.1 % O2 .
Temperature 0.1 .
Optional product :